UPS Accessories
Powertecnique supply a wide range of Simple Network Management Protocol (SNMP) adapters,
USB converters, duplexers and protocol converters to expand the communications capabilities
of Powertecnique UPS and provide ease of management across networks and multi operating
platforms.
NETMAN 101/102
The NetMan network agent allows UPS management across a LAN using any of the main
network communication protocols - TCP/IP, HTTP and network interface (SNMP). NetMan
enabled UPS integrate easily into medium and large sized networks and provide reliable
communications between the UPS and management systems employed.
- configured via TELNET or a serial terminal
- compatible with UPSMon V 5.0 and PowerNETGuard monitoring and control software
- integrated Web server for browser-based display
- Telenetguard modem compatible
- firmware upgradeable through the serial port.
- support's the network interface (SNMP) standard communication protocol with proprietary
RFC 1628 and MIB
MULTICOM 301/302
The MultiCOM 301/302 protocol converter may be used to monitor the UPS using the
MODBUS/JBUS protocol on RS485 or RS232 serial lines. It will also manage a second,
independent RS232 serial line that can be used to connect other devices such as
the Netman 101 or a PC that uses the PowerShield software.
- configuration of the port for MODBUS/JBUS as RS232 or RS485
- management of two independent serial lines
- suitable for integration with Building Management Systems (BMS)
- LED signaling of the communication flow
- firmware upgrade able through the serial port.
MULTICOM 351/352
The MultiCom 351/352 is a serial duplexer that allows two devices to be connected
to a single serial port on a UPS. It can be used where numerous serial connections
and multiple polling of UPS are required, and is ideal for LAN networks with a firewall.
- cascading configuration giving a maximum of 4 serial ports
- LED signaling of the communication flow
- firmware upgrade able through the serial port.
MULTICOM 362 SERIAL/USB PORT
MultiCOM 362 provides a UPS with an additional RS232 serial interface or USB port.
The USB port allows the UPS to communicate with Apple Macintosh computers as well
as Windows and Linux operating systems.
- compatible with USB 1 or 2
- compatible with UPSMon v 5.0.
MULTICOM 372 SERIAL/ESD PORT
MultiCOM 372 provides a UPS with an additional RS232 serial interface port. The
card has Emergency Power Off (EPO) and Remote Shut Down (RSD) inputs with terminal
connections.
- EPO and UPS shutdown interface
- 12Vdc 80mA contact option
MULTICOM 382 CONTACTS/ESD BOARD
MultiCOM 382 provides a set of relay contacts to provide UPS alarm and status indication.
The contacts are connected through terminal connections. Signal contacts include
Emergency Power Off (EPO), Remote Shut Down (RSD), On Battery, On Bypass, Alarm
and Low battery. The contacts are change over or normally open.
- max. 3A current at 250Vac
- signal contact customisation.
MULTI I/O
The Multi I/O device integrates the UPS with control systems with complete configurability
of the input and output signals.
- 8 analog/digital inputs
- 8 relay outputs configured using the UPS and input status
- may communicate with the UPS via RS-232
- can control 2 independent serial lines RS232/RS485 to monitor the UPS and the device
itself with the Modbus/Jbus protocol.
USB CONVERTER
The RS232-USB converter allows UPS without a USB port to connect to Macintosh, Windows
and linux PCs with this type of port.
- compatible with USB 1.2
- compatible with UPSMON V 5.0
MULTIFUNCTION I/O SERIAL LINK/CONTACTS DUPLEXER
Multifunction I/O is a NAOS range accessory with which you can associate the battery
operation, bypass, alarm and battery depleted status reports with dry contacts (maximum
current 8A/250V). The accessory also has an input which is used to set up the configurable
remote on, remote off and remote on/off functions through the UPSTools software
(vers. 1.3.3 or higher). The functions are provided for UPS with firmware version
SWM020-01-16 or higher.
- max. current 8A at 250Vac
- possibility of configuring the signal-to-contact
- associations pass-through serial link for PC connection.
PROFIBUS CONVERTER PROTOCOL CONVERTER
The Profibus Dp Gateway is an accessory with which you can connect a UPS to a Profibus
DP network. With this device management and monitoring of the UPS can be integrated
in a control system based on one of the field buses most widely used in industry
for communication between control/automation systems and distributed I/O.
- PROFIBUS DP-V1 Protocol.
- Configurable address from 1 to 126.
- Configurable baud rate from 9.6 kBaud to 93.75 kBaud
- LED reporting the communication flow.
KIT FOR AS400 AND I-SERIES COMMUNICATION KIT
The IBM AS/400 has a single-level memory management feature that makes it compulsory
for the system to be shutdown in a controlled and orderly manner. Without UPS protection
an AS/400 is not protected from mains failures. A momentary loss of power can cause
hardware damage, data corruption and a lengthy reboot period. The Powertecnique
UPS AS/400 interface kit allows a UPS to be connected to the AS/400 to initiate
an orderly system shutdown on mains failure
- compatible with all AS/400 systems
- supports all the Powertecnique UPS ranges.